15
Russound A-C68 Installation Manual
The Keypad Ports are located on the back of the A-C68 on the left. Connections
at the Keypad Ports are made with RJ45 connectors using T568A CAT-5 wire
configuration. CAT-5 cable length should be no longer than 150 feet from
controller to keypad (also applies when using A-LC3).
If connecting A-K5L or A-K3 keypads to the A-C68, the keypad dip switches
on the front programming center must be set in the DOWN position. For other
A-BUS keypad connections, the dip switch must be set in the UP position. Dip
switches correspond to numbered keypad ports.
For a clean installation when wiring from a Keypad Port, use an RJ45 CAT-5
patch cable to connect from the keypad port to an RJ-45 wall plate (optional).
Using the same RJ45 T568A CAT-5 wiring configuration, use CAT-5 from the
RJ45 wall plate to the keypad.

HUB
A-K5L (back)
A-C68 (back)
1 2 3 4 5 7 86
Keypad Dip Switches
Update
Source
/
Test
Cmd/
Type
Num Src
Code
/
Ke
y
IR Lear
n
Fact Init
Run
Firmware Update
Setup
IR In
1 2 3 4 5 7 86
Keypad Dip Switches
A-C68 (front)
CA
T-5
Cabl
e
Keypad dip switch on A-C68
set in DOWN position
for A-K5L keypa
d
1 2 3 4 5 7 86
Keypad Dip Switches
A-K3 (back)
Keypad dip switch on A-C68
set in UP positio
n
for all other A-BUS keypad
s
Location of dip switches
Wiring standard for
CAT-5 RJ45 connector
L GAIN R
1 2 3 4 5 7 86
Keypad Dip Switches
Keypad dip switch on A-C68
set in DOWN positio
n
for A-K3 keypad
UPGRADE